D-Link DSN-6120 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Redes D-Link DSN-6120. D-Link DSN-6120 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - D-Link iSCSI IP SAN storage

1 D-Link iSCSI IP SAN storage GbE iSCSI to SATA II / SAS RAID IP SAN storage DSN-6110 & DSN-6120 User Manual Version 1.0

Página 2 - Preface

10MPIO Multi-Path Input/Output. MC/S Multiple Connections per Session MTU Maximum Transmission Unit. CHAP Challenge Handshake Authentication Prot

Página 3 - Table of Contents

1003. If user installs anyone of Windows XP, Windows Vista or Windows 7, MC/S is the only option since Microsoft MPIO is supported Windows Server e

Página 4

101A. This is a simple SAN environment. There is only one switch to connect the server and storage. And there is no extra server to be added in the

Página 5

102 Figure 5.10.1.1 5.10.2 Ownership When creating RG, it will be assigned with a prefered owner, the default owner is controller 1. To change t

Página 6 - Chapter 1 Overview

103 Figure 5.10.2.2 (Figure 5.10.2.2: The RG ownership is changed to the other controller.) 5.10.3 Controller status There are four statuses de

Página 7 - 1.1.1 Highlights

1045.11 Replication Replication function will help users to replicate data easily through LAN or WAN from one IP SAN storage to another. The proc

Página 8 - 1.2 RAID concepts

105 Figure 5.11.2 3. If you want the replication port to be on special VLAN section, you may assign VLAN ID to the replication port. The setting w

Página 9 -  Part 2: iSCSI

106 Figure 5.11.5  Create replication job on the source IP SAN storage 1. Click “Create” to create a new replication job. Figure 5.11.6 2. S

Página 10 - 1.2.2 RAID levels

107 Tips If the message displays that there is not enough space for creation, please refer to the section of Configure the snapshot space below for

Página 11 - 1.3 iSCSI concepts

108 5. Choose the backup VD and click “Next”. Figure 5.11.10 6. A new replication job is created and listed on the Replication page. Figure 5

Página 12

109 Figure 5.11.13 3. User can monitor the replication job from the “Status” information and the progress is expressed by percentage. Figure 5

Página 13 -  Controller features

11RAID 30 Striping over the member RAID 3 volumes. RAID 30 needs at least six hard drives. RAID 50 Striping over the member RAID 5 volumes. RAID 50

Página 14 -  Advanced data protection

110 Figure 5.11.16 3. Select the iSCSI node to log on and click “Next”. Figure 5.11.17 4. Choose the same target VD and click “Next”.

Página 15 -  OS support

111 Figure 5.11.18 5. A new target will be added in this replication job as a redundancy path. Figure 5.11.19  Configure the replication job t

Página 16 - 1.4.2 FCC and CE statements

1122. The replication job can be scheduled to run by day, by week or by month. The execution time can be configurable per user’s need. Figure 5.1

Página 17

113 There are three settings in the Replication configuration menu, The Snapshot space specifies the ratio of snapshot space allocated to the sou

Página 18 - Chapter 2 Installation

1145.12 VLAN VLAN (Virtual Local Area Network) is a logical grouping mechanism implemented on switch device using software rather than a hardware

Página 19 - 2.3.2 Front LED lights

115 4. VLAN ID 66 for LAN2 is set properly. Figure 5.12.3  Assign VLAN ID to LAG(Trunking or LACP) 1. After creating LAG, press “OP” button ne

Página 20 - 2.3.3 Install drives

1163. If iSCSI ports are assigned with VLAN ID before creating aggregation takes place, aggregation will remove VLAN ID. You need to repeat step 1

Página 21 - 2.3.4 Rear view

117Chapter 6 Troubleshooting 6.1 System buzzer The system buzzer features are listed below: 1. The system buzzer alarms 1 second when system b

Página 22 - Figure 2.3.4.2 (DSN-6110)

118ERROR SATA PRD mem fail Failed to init SATA PRD memory manager ERROR SATA revision id fail Failed to get SATA revision id ERROR SATA set reg

Página 23

119 RMS events Level Type Description INFO Console Login <username> login from <IP or serial console> via Console UI INFO Con

Página 24 - Figure 2.4.2

12IP SANs are true SANs (Storage Area Networks) which allow several servers to attach to an infinite number of storage volumes by using iSCSI over T

Página 25 - 2.5 Deployment

120INFO BBM status good Battery backup module is good INFO BBM status charging Battery backup module is charging WARNING BBM status fail Batter

Página 26

121INFO Volt recovery Voltage of <string> in JBOD <string> is NORMAL WARNING Therm warn OT Temperature of <string> read as <

Página 27 - Chapter 3 Quick setup

122ERROR CTR memory NG Memory size mismatch ERROR CTR firmware NG Firmware version mismatch ERROR CTR lowspeed NG Low speed inter link is down

Página 28 - Figure 3.1.4.2

123Appendix A. Certification list  iSCSI Initiator (Software) OS Software/Release Number Microsoft Windows Microsoft iSCSI Software Initiator

Página 29

124Dell PowerConnect 2724 Dell PowerConnect 2708 HP ProCurve 1800-24G Netgear GS724T ZyXEL GS2200  Hard drive SAS drives are recommanded on dual c

Página 30 - 3.2.1 Quick installation

125K2A0AD1A) Hitachi Deskstar E7K1000, HDE721010SLA330, 1TB, 7200RPM, SATA 3.0Gb/s, 32MB, NCQ (F/W: ST60A3AA) Hitachi UltraStar A7K2000, HUA722020A

Página 31 - Figure 3.2.1.4

126B. Microsoft iSCSI initiator Here is the step by step to setup Microsoft iSCSI Initiator. Please visit Microsoft website for latest iSCSI initia

Página 32 - Figure 3.2.1.6

127 Figure B.2 Figure B.3 4. It can connect to an iSCSI disk now.  MPIO 5. If run

Página 33 - Figure 3.2.2.1

128 Figure B.4 Figure B.5 8. Click “OK”. Figure B.6

Página 34

129 9. Click “Targets” tab, select the second path, and then click “Connect”. 10. Enable “Enable multi-path” checkbox. Then click “OK”. 11. Done,

Página 35 - Chapter 4 Configuration

13http://www.microsoft.com/downloads/details.aspx?FamilyID=12cb3c1a-15d6-4585-b385-befd1319f825&DisplayLang=en 2. In current Linux distributio

Página 36 - 4.2 System configuration

130 Figure B.10 Figure B.11 17. Select Initiator IP and Target portal IP, and then cli

Página 37 - 4.2.3 Login setting

131 Disconnect 21. Select the target name, click “Disconnect”, and then click “Yes”. Figure B.14 22. Done, the iSCSI device disconnect succes

Página 38 - 4.2.4 Mail setting

132C. From single controller to dual controllers This SOP applies to upgrading from DSN-6110 to DSN6120 as well as from DSN-6410 to DSN-6420. Befor

Página 39 - 4.2.5 Notification setting

133Please follow the steps below to upgrade to dual controller mode. Step 1 Go to “Maintenance\System”. Copy the IP SAN storage serial number. St

Página 40 - Figure 4.2.5.1

134Step 3 Click “confirm”. The system will ask you to shutdown. Please shutdown IP SAN storage. Click Ok.

Página 41 - 4.3 iSCSI configuration

135Go to “Maintenance\Reboot and shutdown”. Click “Shutdown” to shutdown the system. Click Ok. Step 4 Power off DNS-6110 or DSN-6410. Insert the

Página 42 - Figure 4.3.1.2

148. Front-end 4 GbE NIC ports with high availability/load balancing/fail-over support per controller  Microsoft MPIO, MC/S, Trunking, LACP, and

Página 43 - Figure 4.3.1.4

15 Enclosure monitoring 1. S.E.S. inband management 2. UPS management via dedicated serial port 3. Fan speed monitors 4. Redundant power suppl

Página 44 - 4.3.3 Node

16 Drive support 1. SAS 2. SATA II (optional, need SATA Bridge board) 3. SCSI-3 compliant 4. Multiple IO transaction processing 5. Tagged com

Página 45 - Figure 4.3.3.2

17 A. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment

Página 46 -  Change portal:

18Chapter 2 Installation 2.1 Package contents The package contains the following items: 1. DSN-6110/6120 IP SAN storage (x1) 2. HDD trays (x12

Página 47 - 4.3.4 Session

19The drives can be installed into any slot in the enclosure. Slot numbering will be reflected in web UI. Tips It is advisable to install at least

Página 48 - 4.3.5 CHAP account

2Preface Copyright Copyright@2011, D-Link Corporation. All rights reserved. No part of this manual may be reproduced or transmitted without writte

Página 49 - 4.4 Volume configuration

202.3.3 Install drives Note : Skip this section if you purchased a solution populated with drives. To install SAS or SATA drives with no Bridge B

Página 50

21 Figure 2.2.3.3  HDD tray description:  HDD power LED:  Green  HDD is inserted and good.  Off  No HDD.  HDD access LED:  Blue blin

Página 51 - Figure 4.4.1.4

22 Controller 1.  Power supply unit (PSU2).  Fan module (FAN3 / FAN4).  Power supply unit (PSU1).  Fan module (FAN1 / FAN2). Figure 2.3.4.2 (

Página 52 -  PD operation description:

23  Connector, LED and button description:  Gigabit ports (x4).  LED (from left to right) Controller Health LED:  Green  Controller status no

Página 53 - 4.4.2 RAID group

24 1. Shutdown IP SAN storage, then power off. 2. Remove the cover of battery backup module. 3. Insert the battery backup module. Figure 2.4.1

Página 54 - Figure 4.4.2.2

252.5 Deployment Please refer to the following topology and have all the connections ready. Figure 2.5.1 (DSN-6120) Figure 2.5.2 (DSN-6110) 1

Página 55 -  RG operation description:

264. Host server is suggested to logon the target twice (both controller 1 and controller 2), and then MPIO should be setup automatically. (only fo

Página 56 - 4.4.3 Virtual disk

27Chapter 3 Quick setup 3.1 Management interfaces There are three management methods to manage D-Link IP SAN storage, describe in the following:

Página 57 - Figure 4.4.3.2

28 Figure 3.1.4.1 User name: admin Default password: 123456 After login, choose the functions which lists on the left side of window to make any c

Página 58

29 Temperature light:  Green  Temperature is normal.  Red  Temperature is abnormal. Voltage light:  Green  voltage is normal.  Red  vol

Página 59 -  VD operation description:

3Table of Contents Chapter 1 Overview... 61.1 Features...

Página 60

303.2 How to use the system quickly The following methods will describe the quick guide to use this IP SAN storage. 3.2.1 Quick installation Pl

Página 61 - 4.4.4 Snapshot

31 Step2: Confirm the management port IP address and DNS, and then click “Next”. Figure 3.2.1.3 Step 3: Set up the data port IP and click “Next”.

Página 62 - Figure 4.4.4.5

32 Figure 3.2.1.5 Step 5: Check all items, and click “Finish”. Figure 3.2.1.6 3.2.2 Volume creation wizard “Volume create wizard” has a smar

Página 63 - 4.4.5 Logical unit

33different sizes of HDDs, e.g., 8*200G and 8*80G, it lists all possibilities and combination in different RAID level and different sizes. After use

Página 64

34 Figure 3.2.2.2 Step 3: Decide VD size. User can enter a number less or equal to the default number. Then click “Next”. Figure 3.2.2.3 Step 4:

Página 65 - 4.4.6 Example

35Chapter 4 Configuration 4.1 Web UI management interface hierarchy The below table is the hierarchy of web GUI. System configuration System

Página 66 - Figure 4.4.6.4

36 Upgrade  Browse the firmware to upgrade Firmware synchronization  Synchronize the slave controller’s firmware version with the master’s Rese

Página 67

37Check “Change date and time” to set up the current date, time, and time zone before using or synchronize time from NTP (Network Time Protocol) ser

Página 68 - Figure 4.4.6.8

38 Figure 4.2.3.1 Check “Change admin password” or “Change user password” to change admin or user password. The maximum length of password is 12 ch

Página 69 - 4.5 Enclosure management

39 Figure 4.2.4.1 4.2.5 Notification setting “Notification setting” can set up SNMP trap for alerting via SNMP, pop-up message via Windows messe

Página 70 - 4.5.1 Hardware monitor

44.4.1 Physical disk...494.4.2 RAID group

Página 71 - 4.5.2 UPS

40 Figure 4.2.5.1 “SNMP” allows up to 3 SNMP trap addresses. Default community setting is “public”. User can choose the event log levels and defaul

Página 72 - Figure 4.5.2.2

41Most UNIX systems build in syslog daemon. “Event log filter” setting can enable event log display on “Pop up events”. 4.3 iSCSI configuration

Página 73 - 4.5.4 Hard drive S.M.A.R.T

42 Figure 4.3.1.2  Default gateway: Default gateway can be changed by checking the gray button of LAN port, click “Become default gateway”. There

Página 74 - 4.6 System maintenance

43LACP packets to the peer. The advantages of LACP are (1) increases the bandwidth. (2) failover when link status fails on a port. Trunking / LACP

Página 75 - 4.6.2 Event log

44 Figure 4.3.1.5 (Figure 4.3.1.5 shows a user can ping host from the target to make sure the data port connection is well.) 4.3.2 Entity proper

Página 76 - Figure 4.6.2.1

45 Figure 4.3.3.1  CHAP: CHAP is the abbreviation of Challenge Handshake Authentication Protocol. CHAP is a strong authentication method used in

Página 77 - 4.6.3 Upgrade

46 Figure 4.3.3.3 5. Go to “/ iSCSI configuration / CHAP account” page to create CHAP account. Please refer to next section for more detail. 6. C

Página 78 - 4.6.6 Import and export

47 Rename alias: User can create an alias to one device node. 1. Check the gray button of “OP.” column next to one device node. 2. Select “Rena

Página 79 - 4.7 Home/Logout/Mute

48 Figure 4.3.4.1 (iSCSI Session) Check the gray button of session number, click “List connection”. It can list all connection(s) of the session.

Página 80 - 5.1 Volume rebuild

49 3. Click “OK”. Figure 4.3.5.2 4. Click “Delete” to delete CHAP account. 4.4 Volume configuration “Volume configuration” is designed for s

Página 81

56.2 Event notifications ...117A. Certification list...

Página 82 - 5.2 RG migration

50 Figure 4.4.1.1 Step 2: If there is any RG which is in protected RAID level and can be set with dedicate spare disk, select one RG, and then cli

Página 83 - 5.3 VD extension

51 Figure 4.4.1.4  PD column description: Slot The position of a hard drive. The button next to the number of slot shows the functions which can

Página 84 - 5.4 Snapshot

52RAID group.  “Free disk”  This hard drive is free for use.  “Dedicated spare”  This hard drive has been set as dedicated spare of a RG. 

Página 85 - Figure 5.4.1.2

53the indication LED off. More information Show hard drive detail information. 4.4.2 RAID group “RAID group” can view the status of each RAID gr

Página 86 - 5.4.2 Auto snapshot

54 Figure 4.4.2.2 (Figure 4.4.2.2: There is a RAID 0 with 4 physical disks, named “RG-R0”. The second RAID group is a RAID 5 with 3 physical disks,

Página 87 - 5.4.4 Snapshot constraint

55 “Failed”  the RAID group fails.  “Degraded”  the RAID group is not healthy and not completed. The reason could be lack of disk(s) or have

Página 88 - Figure 5.4.4.1

56Command queuing: “Enabled”  Enable disk command queue. (Default) “Disabled”  Disable disk command queue. More information Show RAID group detail

Página 89 - 5.5 Disk roaming

57 Step 2: Confirm page. Click “OK” if all setups are correct. Figure 4.4.3.2 (Figure 4.4.3.2: Create a VD named “VD-01”, from “RG-R0”.) Step 3:

Página 90 - 5.6 VD clone

58number the background priority of a VD is, the more background I/O will be scheduled to execute. Status The status of virtual disk:  “Online” 

Página 91

59The unit can be displayed in GB or MB. #Snapshot Number of snapshot(s) that have been taken. RG name The RG name of the virtual disk  VD opera

Página 92 - Figure 5.6.6

6Chapter 1 Overview 1.1 Features D-Link DSN-6000 series IP SAN storage provides non-stop service with a high degree of fault tolerance by using D

Página 93

60editing.  “Disabled”  Disable AV-media mode. (Default) Type:  “RAID”  the virtual disk is normal. (Default)  “Backup”  the virtual disk i

Página 94

614.4.4 Snapshot “Snapshot” can view the status of snapshot, create, and modify snapshots. Please refer to next chapter for more detail about snap

Página 95 - Figure 5.6.14

62 Figure 4.4.4.4 Figure 4.4.4.5 (Figure 4.4.4.5: This is the snapshot list of “VD-01”. There are two snapshots. Snapshot VD “SnapVD-01” is expos

Página 96 - Figure 5.6.15

63 “Good”  The snapshot is good.  “Failed”  The snapshot fails. Exposure Snapshot VD is exposed or not. Right The right of snapshot:  “Re

Página 97 - 5.7 SAS JBOD expansion

64 Figure 4.4.5.1 Figure 4.4.5.2  LUN operation description: Attach Attach a logical unit number to a virtual disk. Detach Detach a logical

Página 98 - 5.8 MPIO and MC/S

65 4.4.6 Example The following is an example to create volumes. This example is to create two VDs and set a global spare disk.  Example This ex

Página 99 - Figure 5.8.2

66Step 2: Create VD (Virtual Disk). To create a data user volume, please follow the procedures. Figure 4.4.6.3 1. Select “/ Volume configuratio

Página 100 - 5.9 Trunking and LACP

672. In “/ Volume configuration / Logical unit”, click “Attach”. The procedures are as follows: Figure 4.4.6.5 1. Select a VD. 2. Input “Host

Página 101 - 5.10.1 Perform I/O

68 Figure 4.4.6.7 (Figure 4.4.6.7: Slot 4 is set as a global spare disk.) Step 5: Done. Delete VDs, RG, please follow the below steps. Step 6:

Página 102 - 5.10.2 Ownership

69Step 8: Delete a RG (RAID group). To delete a RAID group, please follow the procedures: 1. Select “/ Volume configuration / RAID group”. 2. Se

Página 103 - 5.10.3 Controller status

71.1.1 Highlights  D-Link DSN-6110/6120 feature highlights Host Interface 8 x iSCSI GbE ports (DSN-6120) 4 x iSCSI GbE ports (DSN-6110) Drive In

Página 104 - 5.11 Replication

70 4.5.1 Hardware monitor “Hardware monitor” can view the information of current voltages and temperatures.

Página 105 - Figure 5.11.4

71Figure 4.5.1.1 If “Auto shutdown” is checked, the system will shutdown automatically when voltage or temperature is out of the normal range. For

Página 106

72First, connect the system and APC UPS via RS-232 for communication. Then set up the shutdown values (shutdown battery level %) when power is faile

Página 107 - Figure 5.11.9

73 “UPS shutdown in progress”  “Batteries failed. Please change them NOW!” Battery Level (%) Current power percentage of battery level. 4.5.3

Página 108 -  Run the replication job

74S.M.A.R.T. only supports SATA drives. SAS drives do not have this function now. It will show N/A in the web page for SAS drives. Figure 4.5.4.1

Página 109

75  Status description: Normal Dual controllers are in normal stage. Degraded One controller fails or has been plugged out. Lockdown The firmwa

Página 110 - Figure 5.11.17

76 Figure 4.6.2.1 The event log is displayed in reverse order which means the latest event log is on the first / top page. The event logs are act

Página 111

77 4.6.3 Upgrade “Upgrade” can upgrade firmware. Please prepare new firmware file named “xxxx.bin” in local hard drive, then click “Browse” to sel

Página 112 - Figure 5.11.21

784.6.5 Reset to factory default “Reset to factory default” allows user to reset IP SAN storage to factory default setting. Figure 4.6.5.1 Rese

Página 113

794.6.7 Reboot and shutdown “Reboot and shutdown” can “Reboot” and “Shutdown” the system. Before power off, it’s better to execute “Shutdown” to f

Página 114 - 5.12 VLAN

8 1.2 RAID concepts RAID is the abbreviation of “Redundant Array of Independent Disks”. The basic idea of RAID is to combine multiple drives togeth

Página 115 - Figure 5.12.5

80Chapter 5 Advanced operations 5.1 Volume rebuild If one physical disk of the RG which is set as protected RAID level (e.g.: RAID 3, RAID 5, or

Página 116

81 Rebuild operation description: RAID 0 Disk striping. No protection for data. RG fails if any hard drive fails or unplugs. RAID 1 Disk mirrori

Página 117 - Chapter 6 Troubleshooting

825.2 RG migration To migrate the RAID level, please follow below procedures. 1. Select “/ Volume configuration / RAID group”. 2. Check the gra

Página 118 - EMS events

83To do migration, the total size of RG must be larger or equal to the original RG. It does not allow expanding the same RAID level with the same ha

Página 119 - Battery backup events

84 Figure 5.3.2 Tips The size of VD extension must be larger than original. Caution VD Extension cannot be executed during rebuilding or migra

Página 120 - JBOD events

855.4.1 Create snapshot volume To take a snapshot of the data, please follow the procedures. 1. Select “/ Volume configuration / Virtual disk”.

Página 121 - HAC events

86 1. There are two methods to clean all snapshots. In “/ Volume configuration / Virtual disk”, check the gray button next to the VD number; click

Página 122 - Replication events

875.4.3 Rollback The data in snapshot VD can rollback to original VD. Please follow the procedures. 1. Select “/ Volume configuration / Snapshot

Página 123 - A. Certification list

88 Figure 5.4.4.1 On Linux and UNIX platform, a command named sync can be used to make the operating system flush data from write caching into disk

Página 124

89For example, there are two or more snapshots existed on a VD and the latest snapshot keeps growing. When it comes to the moment that the snapshot

Página 125 - SATA 2.5”

9both data cache and accessed physical disks. WB Write-Back cache-write policy. A caching technique in which the completion of a write request is si

Página 126 - B. Microsoft iSCSI initiator

905.6 VD clone The user can use VD clone function to backup data from source VD to target VD, set up backup schedule, and deploy the clone rules.

Página 127 -  MPIO

91 3. Here are the objects, a Source VD and a Target VD. Before starting clone process, it needs to deploy the VD Clone rule first. Click “Configur

Página 128 - 8. Click “OK”

92 Figure 5.6.5 The threshold setting will monitor the usage amount of snapshot space. When the used snapshot space achieves its threshold, system

Página 129 -  MC/S

93 Figure 5.6.7 6. Select the target VD. Then click “Confirm”. Figure 5.6.8 7. Now, the clone target “TargetVD_R6” has been set. Figure 5.6.

Página 130

94 Figure 5.6.10 9. The default setting will create a snapshot space automatically which the capacity is double size of the VD space. Before star

Página 131 - Figure B.14

95 Figure 5.6.13 12. There are “Set Clone schedule” and “Clear Clone schedule” in this page. Please remember that “Threshold” and “Restart the tas

Página 132

96the clone process. Each time the clone snapshot failed, it means that the system loses the reference value of incremental data. So it will start a

Página 133

97 5.7 SAS JBOD expansion 5.7.1 Connecting JBOD D-LINK DSN-6000 series support up to 4 additional SAS/SATA JBODs for capacity expansion. When

Página 134 - Click Ok

98 Figure 5.7.2.1 2 Choose a JBOD which wants to upgrade. 3 Please prepare new firmware file in local hard drive, then click “Browse” to select t

Página 135

99 2. MC/S: MC/S (Multiple Connections per Session) is a feature of iSCSI protocol, which allows combining several connections inside a single sess

Comentários a estes Manuais