DGS-3200 Series Layer 2 Managed Gigabit Ethernet Switch Web UI Reference Guide
228
Offset 48-63 - Enter a value in hex form to mask the packet from byte 48 to byte 63.
Offset 64-79 - Enter a value in hex form to mask the packet from byte 64 to byte 79.
Time Range
Name
Tick the check box and enter the name of the Time Range settings that has been previously
configured in the Time Range Settings window. This will set specific times when this access
rule will be implemented on the Switch.
Ports
Ticking the All Ports check box will denote all ports on the Switch.
Click Apply to implement the changes.
To view the settings of a previously correctly configured rule, click the corresponding Show Details button on the CPU Access
Rule List window to view the following window:
Figure 7 - 43. CPU Access Rule Detail Information window for Packet Content
Time Range Settings
In conjunction with the Access Profile feature, the time range settings determine a starting point and an ending point, based on
days of the week, when an Access Profile configuration will be enabled on the Switch. Once configured here, the time range
settings are to be applied to an access profile rule using the Access Profile table. The user may enter up to 64 time range entries on
the Switch.
To view the following window, click ACL > Time Range Settings:
Figure 7 - 44. Time Range Settings window
The user may adjust the following parameters to configure a time range on the Switch:
Parameter Description
Range Name
Enter a name of no more than 32 alphanumeric characters that will be used to identify this time
range on the Switch. This range name will be used in the Access Profile table to identify the
access profile and associated rule to be enabled during this time range.
Hours
This parameter is used to set the time in the day that this time range is to be enabled using the
following parameters:
Start Time - Use this parameter to identify the starting time of the time range, in hours,
minutes and seconds, based on the 24-hour time system.
End Time - Use this parameter to identify the ending time of the time range, in hours,
Vista de página 241